Programming Manual EURO
RINS1291-3 Page: 19
Confirm Group
Enter the Confirm Group if used.
Press the key
Input Name
If you would like to enter a name for the
input, select the key. Text programming
is described on page: 9. Select the key.
Repeat all the above for further inputs, or
press the key to return to the Engineers
Menu.
NOTE: After programming the inputs, it is necessary to exit the Engineer Menu for
the programming to take effect, before the inputs are walk tested, etc.
*These are not available on the EURO 28.
4.6.7 Shunt Inputs*
*This feature is not available on the EURO 28.
A shunt group may consist of any number of inputs programmed as Intruder, Tamper, Day
Alarm and Entry Route types. These must all be allocated in the same Area. NOTE: These will
need to be programmed first.
The inputs in the shunt group/list will only activate after 10 seconds of the nominated shunt
input. For example, if input 1 is programmed as ‘Shunt Input’, and inputs 2 and 3 are
programmed as “Day Alarm”, then once input 1 has been opened, after 10 seconds inputs 2
and 3 become active. (Inputs 2 and 3 will not become live after 10 seconds if either detector is
in alarm condition).
Action Status Outputs
Shunt Input closed
(shunted)
Inputs within the shunt list are
inactive
The ‘Follow Input’ output is live
Shunted Input
triggered
No response
Shunt Input opened
(unshunted)
-
The ‘Follow Input’ output clears.
The ‘Shunt Fault’ output is live for
10 seconds.
After 10 seconds
Inputs in the shunt list are
active
Indications off.
Shunt Input opened
with an active detector
(attempting to
unshunt)
-
The ‘Follow Input’ output clears.
The ‘Shunt Fault’ output pulses
until the shunt is reset or the
input fault clears.
Active input clears -
The ‘Shunt Fault’ output is live for
10 seconds. (Will not function
correctly on an ATE pin).
After 10 seconds
Inputs in the shunt list are
active
Indications off.
Shunted input
triggered (whilst not
triggered)
Normal input response
(Note: depends upon the status of
the Area in which the shunt is
located).